Rev. 1.00 12-02-13 4/41
Software support for the ADSL interface is introduced for SN4991 Models. The configuration of
these is equal to the existing models with ADSL interfaces.
12128 RTP through VPN broken
Affected platforms: SN4660/70, SN4940/50/60, SN4970/80/90, SN5480/90
The „[no] rtp-encryption‟ command in the „ip interface‟ configuration mode is used to give the
system the ability to send locally generated RTP traffic through VPN. On the above listed
platforms that command caused a one-way voice connection where the outgoing stream was
suppressed.
12130 Wrong drop cause reported by SIP endpoints, resulting in failed call hunting
SmartWare build R6.T 2012-12-03 introduced an incorrect processing of the drop cause from
SIP endpoint. Whenever a SIP call was dropped it reported “normal call clearing” no matter
what the real cause was. Among others this resulted call failures when using a hunt group.
12131 Spelling error corrected on BGP configuration web page
It now says “Border” instead of “Boader”
12135 SN4660/70 cooling fan speed adjusted
The speed of the cooling fan on SN4660/70 models has reduced for lower temperatures.
Build Series 2012-12-03
11863 SIP supports TCP flows according to RFC5626
SmartWare supports now the „User Agent Procedures‟ from RFC5626 with the exception of
„Keep-Alive with STUN‟. Registrations can now open a TCP flow to the registrar and keep it
open through CRLF keep-alive or other messages. Through that flow calls can traverse through
NAT and reach the registered user. See full details in the New configuration commands section.
11906 SNMP OID for DSL card firmware version
It is now possible to get the installed firmware version of any DSL daughter cards (ADSL or
G.SHDSL) via SNMP get or walk requests. Please check the latest MIB file on our official
website for the correct OID.
11916 Support for SN4832/LLA and SN4834/LLA models
Software support for the two new SmartNode models SN4832/LLA and SN4834/LLA has been
introduced. These products can be used in pairs as leased line extensions over ADSL with up
to 4 channels.
11943 New NTP server in factory-config
The factory-config of all models has been updated to use the NTP server pool.ntp.org.